SERVICE
LETTER #35
DATE:
August 19, 1994
SUBJECT:
Rotax 582 Choke Control
APPLICABILITY:
All Rotax 582 Powered Kitfox's
COMPLIANCE:
As required if problems develop
FROM:
SkyStar Aircraft Product Development Department
Some
builders have reported two minor problems with the choke control system
used on the 582. The first
problem is that the choke cables are long enough that the knurled
adjustment at the carburetors is all the way out.
The second problem is that the cable bead at the actuator end can
pull through the plastic arm, effectively disabling
the carb's choke.
One
modification addresses both problems.
Remove the black plastic choke actuator from the instrument
panel, and disassemble the actuator by removing the roll pin and pulling
off the back cover to access the cable bead and motion arm.
Remove the cables, and drill a 1/16" hole through the most
aft wall of the bead retaining box, and then carefully slot down to the
hole. Reassemble the
control with the bead aft of the aft wall, and leave out the spring.
The drawing included with this letter will help you identify the
parts. This modification
makes the bead more secure in the action arm, and effectively shortens
the cables. Readjust the
chokes at the carburetors after re-installing the choke control on the
aircraft.
If
you have any questions about this Service Letter, contact Customer
Service at 208-466-1711.
|